We use cookies to ensure that we give you the best experience on our website. If you continue without changing your settings, we´ll assume that you are happy to receive all cookies on our Schlüter Website. However, if you would like to, you can change your cookie settings at any time. Further information

logo

Schlüter®-TROBA

Installation

  1. The load-bearing substrate and the waterproofing membrane placed on it, in compliance with DIN 18 195, Part 5, must be adequately sloped toward and connected to the designated drainage exit.
  2. Irrespective of the direction of slope, Schlüter®-TROBA shall be loosely laid over the waterproofing membrane. Adjacent lengths are placed and overlapped along the flat edges, while the ends of two courses are overlapped by at least one row of dimples.
  3. The surface assembly is installed directly over the placed Schlüter®-TROBA according to current industry standards.
  4. Please note: With respect to edging pro- files, flexible joints, and floor/wall transitions, please refer to the appropriate profiles from our product range.

Contact Schlüter-Systems Ltd

Units 3-5 Bardon 22,
Beveridge Lane, Coalville,
Leicestershire, LE67 1TE
Phone: +44 (0) 1530 813396

Quick contact list

Reach the department of your choice directly via email:

image
Write To Us!

Do you have a question or suggestion?

Further information

on our products and specifications can be found here:

Legend "Products"

We use the following symbols and abbreviations to illustrate our price charts.

image image

= new products

= radius perforation available   

 

Dimensions:
H = height
L = length
B = width


Packaging:
PL = euro pallet 
KV = case packaging 
BV = bundle (there is a 10 item bundle packaging for all the profile types)
P = box packaging 
R = roll
St. = unit