  1. Schlüter-RONDEC-DB can be used with tiles in thicknesses from 6 to 12 mm.
  2. Apply tile adhesive to the area where the tile covering will end, using a notched trowel. If Schlüter-RONDEC-DB is to be used as edging for an external wall corner, first tile one wall completely; then apply tile adhesive along the edge area of the second wall.
  3. Press the perforated anchoring leg of Schlüter-RONDEC-DB firmly into the adhesive and align it.
  4. Trowel additional tile adhesive over the perforated anchoring leg to ensure full coverage.
  5. Firmly press the adjoining tiles into place and align them. Full coverage must be obtained between the tile and the profile’s anchoring leg.
  6. Completely fill the space between the tile and the profile with grout.
  7. Use suitable materials and tools for the sensitive surfaces to avoid scratches or other damage. Residue of adhesive, plaster or render should be removed immediately, especially from aluminium finishes.

Contact Schlüter-Systems Ltd

Units 3-5 Bardon 22,
Beveridge Lane, Coalville,
Leicestershire, LE67 1TE
Phone: +44 (0) 1530 813396

Quick contact list

Reach the department of your choice directly via email:

image
Write To Us!

Do you have a question or suggestion?

Further information

on our products and specifications can be found here:

Metal surfaces
Metal surfaces

All surfaces at a glance

Legend "Products"

We use the following symbols and abbreviations to illustrate our price charts.

image image

= new products

= radius perforation available   

 

Dimensions:
H = height
L = length
B = width


Packaging:
PL = euro pallet 
KV = case packaging 
BV = bundle (there is a 10 item bundle packaging for all the profile types)
P = box packaging 
R = roll
St. = unit