Notes regarding movement joints:
Schlüter-DITRA-SOUND must be separated above the existing movement joints in the substrate. In accordance with the applicable construction standards, movement joints must be continued in the tile covering. The same standards specify that coverings made of large format pavers over Schlüter-DITRA-SOUND must be divided into fields with movement joints. Please refer to the installation information for the various profile types in the Schlüter-DILEX product range. Depending on the anticipated movements, profiles such as Schlüter-DILEX-BT or Schlüter-DILEX-KSBT should be installed over structural movement joints.
Notes regarding edge joints:
The build up of tensions must be ruled out at the edge of coverings; e.g. at upright construction elements or fl oor/wall transitions. The edge joints and connection joints must meet the applicable professional regulations. Their dimensions must be sufficient to rule out the build up of tensions. In this case, Schlüter-DITRA-SOUND-RSK 630 should be installed as an edge strip. Please refer to the installation information for the various profile types in the Schlüter-DILEX product range for instructions on creating edge or connection joints at transitions to walls or skirtings.



   